Our ControlLogix® 5570 Controllers are available in standard, safety, extreme temperature, and On-Machine models suitable for process, motion, discrete, and high-availability applications. Additional required software may include RSNetWorx configuration software and RSLinx communication software. ControlLogix System User Manual.
Advertising
ControlLogix EtherNet/IP Module 9
Rockwell Automation Publication 1756-IN603C-EN-P - April 2010
Set the Network Address
The module ships with the rotary switches set to 999 and BOOTP enabled. You
can set the network Internet Protocol (IP) address three ways.
can set the network Internet Protocol (IP) address three ways.
•
Use the rotary switches on the top of the module.
•
Use a BOOTP server or Dynamic Host Configuration Protocol
(DHCP) server, such as Rockwell Automation BOOTP/DHCP.
(DHCP) server, such as Rockwell Automation BOOTP/DHCP.
•
Use the Rockwell Automation RSLinx or RSLogix 5000 software.
The module reads the rotary switches first to determine if they are set to a valid
number for the last portion of the IP address. Valid numbers range from
001…254. When the switches are set to a valid number, the module’s IP address
is 192.168.1.
number for the last portion of the IP address. Valid numbers range from
001…254. When the switches are set to a valid number, the module’s IP address
is 192.168.1.
xxx (where xxx represents the number set on the switches). The
module’s subnet mask is 255.255.255.0 and the gateway address is set to 0.0.0.0.
The module does not have a host name assigned, or use any Domain Name
System when using the rotary switch settings.
The module does not have a host name assigned, or use any Domain Name
System when using the rotary switch settings.
Item
Description
1
Top of module
2
Rotary switches
3
Front of module
2
3
1
31587
Advertising
Popular Brands
Popular manuals
MVI56E-AFC
ProSoft Technology’s MVI56E-AFC in-chassis flow computer solution allows you to combine the power and scalability of a ControlLogix® automation system with the functionality typically only seen in a stand-alone flow computers or dedicated measurement RTU’s. This provides you with the industry standard calculations, archiving, and reporting needed for custody transfer and allocation based measurement functions for Oil and Gas operations.
By combining automation and measurement functions into a single solution, this helps to reduce overall support and integration costs for Oil and Gas applications while also decreasing your overall capital spend. This simplified solution allows you to optimize your resources.
Controllogix 5000 Manual
In addition, because our flow computer sits in a ControlLogix system, you can take advantage of Rockwell Automation’s distributed I/O capability, wide range of communications protocols, and ProSoft’s wireless radios to greatly reduce wiring to your transmitters and I/O devices.
Since the module operates as a co-processor for measurement related functions to the ControlLogix system, and as measurement requirements of the site grow, you can simply add an additional MVI56E-AFC module to increase your measurement capabilities to an individual site. A truly scalable automation and measurement solution.
Architectures
Features and Benefits
- Meter runs: The module can calculate up to 16 meter runs with four streams per run simultaneously, making it cost-effective, since more meters can be connected to a single flow computer.
- Modbus capabilities: Remote configuration and diagnostics via Ethernet (Modbus® TCP/IP). Flexible serial port configurations allow for either two Modbus slave ports or one Modbus slave and one Modbus Master port. All data, including configuration, calculated results, and historical archives, are available using either the Modbus TCP/IP server or Modbus slave serial ports.
- Customized Modbus Data Mapping: Remapping to a virtual slave enables data concentration, reducing bandwidth load on the communication system.
- Auditability: Our configuration software provides the ability to download and view archives and events. Audit Scan captures process inputs and calculated results as 'snapshots”, allowing verification of calculations. The Event Log records significant events and alarms. Hourly and daily archives are configurable historical records of user-selected data. The data can be viewed online, printed, or saved to a file in .txt or .csv format. Archive data can be exported to Flow-Cal .cfx format. Meter calibration and verification are stored on the module.
- Meter proving: Allows for meter proving with 3 configurable prover types.
- Security: Password protection schemes are available to control user access and log meter calibration and verification activities. A built-in web server allows local/remote configuration, monitoring, and wireless network diagnostics.
Configuration
The EAFC Manager is a free Windows 7-based configuration, reporting, and monitoring tool provided with all MVIxxE-AFC modules. Project configurations may be uploaded, downloaded, and saved to the PC under user-selectable file names.
Specifications
General Specifications
- The module is recognized by the processor as an Input/Output module.
- The included Add-On Instruction (AOI) files are used for data transfers between the module and processor, reducing configuration time.
- Configuration is downloaded over Ethernet by way of the Modbus TCP/IP servers, or delivered by user-defined ladder.
Functional Specifications
The MVI56E-AFC operates as a powerful flow computer module, augmenting the operation of the ControlLogix processor by providing a dedicated and accurate set of flow calculations.
- Calculates flow rates, accumulated volumes, accumulated mass, and (for gas product) accumulated energy.
- Calculation results are transferred to processor memory and may also be transferred to a SCADA host using Modbus serial or Modbus TCP/IP.
- User-configurable, allowing each of the meter runs to be individually set up to meet the specific requirements of an application.
Archiving
- Supports data archiving and event logging.
- Data archiving is available for each meter run, as two separately configurable files, one called “hourly” and the other called “daily”, whose records are intended to implement the Quantity Transaction Records (QTRs) required by applicable measurement standards. Under default configuration:
- (a) Records are written once each hour to the “hourly” file and once each day to the “daily” file, with additional records written to both files upon occurrence of an event that could affect measurement results (such as the change in value of a significant parameter).
- (b) Each record consists of 100 registers formatted with up to 50 data point values selected as being appropriate for the meter’s configuration (type, product, etc.) and compliant with QTR requirements.
- (c) Each file is formatted for a few of the most recent records to be kept in higher-speed local storage plus 1440 more records in larger-capacity, slower “extended” storage.
- Logging feature provides storage of up to 2,000 events and separately 2000 alarms.
Configurable Options
- User-selectable units for totalizers and flow rates on a per-channel basis.
- Roll-over value for resettable and non-resettable totalizers for every meter channel.
- Process analog input units and ranges (pressure, temperature, differential pressure, density) from analog input modules and pulse inputs from pulse/frequency input modules in a ControlLogix chassis.
- Fluid selection provides a choice of several liquid groups or gas measurement, using AGA, API, and/or ISO calculations.
- Event log reports for all security-sensitive configuration data (for example, orifice diameter) are date- and time-stamped. This data can be saved to disk for importing into any spreadsheet or printed as a hard copy.
Modbus Interface
- SCADA communication is provided by the Modbus TCP/IP server and Modbus slave serial ports.
- Modbus table may be re-mapped as a virtual Modbus slave for user-assigned contiguous register polling by a SCADA client/master (up to 20,000 registers).
- Poll remote devices (such as a Gas Chromatograph) by utilizing the Modbus Master serial port.
- Alarm, event, and meter archive log files may be downloaded in Enron Modbus format.
System Requirements -EAFC Manager
This configuration software is designed for Microsoft Windows 7. Minimum hardware requirements for a Windows 7 system are as listed below. More advanced operating systems have significantly higher minimum requirements regardless of EAFC Manager minimum requirements.
- 1 GHz or faster 32-bit (x86) or 64-bit (x64) processor
- 1 GB RAM (32-bit) or 2 GB RAM (64-bit)
- 16 GB available hard drive space (32-bit) or 20GB (64-bit)
- Assigned IP Address
Hardware
Specification | Description |
Backplane Current Load | 800 mA @ 5 Vdc 3 mA @ 24 Vdc |
Operating Temperature | 32°F to 140°F (0°C to 60°C) |
Storage Temperature | -40°F to 185°F (-40°C to 85°C) |
Shock Vibration | 30g operational, 50g non-operational 5g from 10 Hz to 150 Hz Coolpad note 3 user manual download. It should now ask whether you want to install ADB system-wide. Type ' Y' and hit enter. |
Relative Humidity | 5% to 95% RH, with no condensation |
LED Indicators | Module Status, Backplane Transfer Status, Application Status, Serial Activity |
Ethernet port | |
1 Ethernet Application Port | 10/100 Mbps, RJ45 Link and Activity LED Auto crossover (Auto MDIX) |
Serial Application Ports (P1 & P2) | |
2 Serial Application Ports | RJ45 (DB-9M with supplied cable) RS-232, RS-485, RS-422 jumper selectable RS-232 handshaking configurable 500V optical isolation from backplane Full hardware handshaking control, providing radio, modem and multi-drop support Apple macbook pro 13 user manual. |
Shipped with Unit | (2) RJ45 to DB-9M cables (1) 6-foot DB-9F to DB-9F null modem cable |
Downloads
MVI56E-AFC Datasheet | 343.05 kB | Last Modified 11/06/2019 |
MVI56-AFC vs MVI56E-AFC Comparison | 27.20 kB | Last Modified 11/06/2019 |
MVI56E-AFC FAQ Sheet | 325.83 kB | Last Modified 11/06/2019 |
MVI56E-AFC AddOn Instructions | 406.54 kB | Last Modified 11/06/2019 |
MVIxxE-AFC Reference Guide | 7.70 MB | Last Modified 11/06/2019 |
MVI56E-AFC Release Notes | 576.03 kB | Last Modified 11/06/2019 |
MVIxxE-AFC Setup and Configuration Guide | 6.26 MB | Last Modified 11/06/2019 |
MVIxxE-AFC AER Directive 017 | 811.23 kB | Last Modified 11/06/2019 |
MVI56E-AFC Installer Certification Requirements | 1.58 MB | Last Modified 11/06/2019 |
ProSoft EAFC Export Utility - User Manual | 2.26 MB | Last Modified 11/06/2019 |
ProSoft EAFC Manager | ||
Technical Note - MVI56E-AFC or MVI69E-AFC - How to Fetch Archives | 295.17 kB | Last Modified 10/02/2019 |
Technical Note - Updating MVI56E-AFC Network Configuration using API | 902.47 kB | Last Modified 11/07/2019 |
Videos
Setting up your ProSoft Flow Computer for ControlLogix
Controllogix 5000 Programming Manual Pdf
Certifications
Gateway User's Manual Download
Ex Certificate (ATEX Directive) | 81.01 kB | Last Modified 11/22/2019 |
CB Safety | 327.83 kB | Last Modified 05/20/2014 |
DNV GL | 218.23 kB | Last Modified 05/25/2016 |
UL/cUL; Class 1, Div 2 | 430.73 kB | Last Modified 02/27/2019 |
Declaration of Conformity (RoHS/CE) | 299.08 kB | Last Modified 08/14/2018 |